1.
ABCS health sci ; 48: :e023302, 14 fev. 2023. tab, ilus
Article in English | LILACS | ID: biblio-1438260

ABSTRACT

INTRODUCTION: The measurement of the health-related quality of life construct can reveal the positive repercussions on the lives of patients undergoing corrective valve procedures, as well as revealing points that prevent new surgical approaches. OBJECTIVE: To identify the health-related quality of life of valvular heart disease in the perioperative period of conventional valve surgery. METHODS: This is an integrative literature review. Searches were performed independently in four databases using controlled and uncontrolled descriptors. Eligibility criteria were: original articles that addressed the assessment of the health-related quality of life of valvular patients undergoing valve repair and/or valve prosthesis implantation; in Portuguese, English, and Spanish; with a time frame for convenience between 2015 and 2019. RESULTS: 14 studies comprised the final review sample, despite being studies conducted in different countries and with different designs, it was possible to verify the improvement in health-related quality of life when evaluated through generic instruments in valvular patients after valve surgery. However, in studies in which the assessment of the construct occurred through specific instruments, the existence of factors that can interfere with the quality of life of patients undergoing valve implantation was revealed. CONCLUSION: It was noticed that there was generally an improvement in health-related quality of life after the surgical intervention.


INTRODUÇÃO: A mensuração do constructo qualidade de vida relacionada à saúde pode revelar as repercussões positivas na vida dos pacientes submetidos a procedimentos valvares corretivos, bem como revelar pontos que para prevenção de novas abordagens cirúrgica. OBJETIVO: Identificar a qualidade de vida relacionada à saúde de valvopatas no perioperatório de intervenção cirúrgica valvar convencional. MÉTODO: Trata-se de uma revisão integrativa da literatura. As buscas foram realizadas de forma independente, em quatro bases de dados por meio de descritores controlados e não controlados. Os critérios de elegibilidade foram: artigos originais que abordassem a avaliação da qualidade de vida relacionada à saúde de valvopatas submetidos à plastia valvar e/ou implante de prótese valvar; nos idiomas português, inglês e espanhol; com recorte temporal por conveniência entre 2015 e 2019. RESULTADOS: 14 estudos compuseram a amostra final da revisão, apesar de serem estudos realizados em distintos países e com diferentes delineamentos foi possível verificar a melhora da qualidade de vida relacionada à saúde quando avaliada por meio de instrumentos genéricos em valvopatas após a intervenção cirúrgica valvar. Todavia, nos estudos em que a avaliação do constructo ocorreu por meio de instrumentos específicos, foi revelada a existência de fatores que podem interferir na qualidade de vida dos pacientes submetidos aos implantes valvares. CONCLUSÃO: Percebeu-se que geralmente houve melhora da qualidade de vida relacionada à saúde após a intervenção cirúrgica.


Subject(s)
Quality of Life , Surgical Procedures, Operative , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Perioperative Period , Heart Valve Diseases
3.
J. Transcatheter Interv ; 30: eA20210020, 20220101. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1400033

ABSTRACT

A troca valvar mitral transcateter apresenta-se como uma nova opção terapêutica para o tratamento de próteses cirúrgicas degeneradas em pacientes com alto risco cirúrgico. É crescente o número de procedimentos valve-in-valve mitral ao longo dos últimos anos. O presente caso relata uma experiência inicial com esse tipo de procedimento, sendo efetivado de forma segura e eficaz em uma paciente idosa de alto risco cirúrgico para retroca valvar.


Transcatheter mitral valve replacement is a new option to treat deteriorated surgical prosthesis in high surgical risk patients. The number of valve-in-valve mitral procedures has been growing in the last few years. This case reports an initial experience with this type of procedure, safely and effectively performed in an elderly female patient with high-risk for valve replacement.

10.
Arq. bras. cardiol ; 114(1): 12-22, Jan. 2020. tab, graf
Article in English | LILACS | ID: biblio-1055099

ABSTRACT

Abstract Background: Prosthesis-patient mismatch (PPM) is associated with worse outcomes. Objective: Determine the frequency and evaluate preoperatory variables independently associated with severe PPM in a tertiary hospital focused on Public Health Care. Methods: A total of 316 patients submitted to aortic valve replacement, who had echocardiography performed within the first 30 days after surgery, were retrospectively analyzed. The indexed effective orifice area (iEOA) of the prosthesis was used to classify the patients into three groups, according to PPM, considering body mass index (BMI): severe PPM (iEOA) < 0.65 cm2/m2), mild to moderate PPM (iEOA, 0.65 cm2/m2 - 0.85 cm2/m2) and without PPM (iEOA > 0.85 cm2/m2) for a BMI < 30 kg/m2 and severe PPM (iEOA) < 0.55 cm2/m2), mild to moderate (iEOA, 0.55 cm2/m2- 0.70 cm2/m2) and without PPM (iEOA > 0.7 cm2/m2) for a BMI > 30 kg/m2. Statistical significance was considered when p < 0.05. Results: iEOA was obtained in 176 patients. The frequency of severe and moderate PPM was 33.4% and 36.2%, respectively. Severe PPM patients were younger and had larger BMI, but smaller left ventricular outflow tract diameter (LVOTD). The independent variables used to predict severe PPM were male gender, BMI > 25 kg/m2, age < 60 years, LVOTD < 21 mm, and rheumatic etiology with an area under the ROC curve of 0.82. Conclusion: The frequency of severe PPM is high in a Brazilian population representative of the Public Health System, and it is possible to predict PPM from preoperative variables such as rheumatic valvular disease, gender, BMI, age and LVOTD.


Resumo Fundamento: A desproporção entre o tamanho da prótese aórtica-paciente (DPP) está associada a maior mortalidade. Objetivo: Determinar a frequência e avaliar variáveis ​​pré-operatórias associadas à DPP acentuada no cenário da saúde pública em hospital terciário. Métodos: 316 pacientes submetidos à troca valvar aórtica (TVA), com ecocardiograma realizado nos primeiros 30 dias após cirurgia, foram analisados retrospectivamente. A área de orifício efetivo indexado (AOEi) da prótese foi utilizada para classificar os pacientes em três grupos de acordo com a DPP, considerando o índice de massa corporal (IMC): DPP acentuada (AOEi) < 0,65 cm2/m2, DPP discreta a moderada (AOEi, 0,65 cm2/m2 - 0,85 cm2/m2) e sem DPP (iEOA > 0,85 cm2/m2) para IMC < 30 kg/m2 e DPP acentuada (AOEi) < 0,55 cm2/m2), discreta a moderada (AOEi, 0,55 cm2/m2 - 0,70 cm2/m2) e sem DPP (AOEi > 0,7 cm2/m2) para IMC > 30 kg/m2. Significância estatística foi considerada com p < 0,05. Resultados: A AOEi foi obtida em 176 pacientes. A frequência de DPP acentuada foi de 33,4% e moderada de 36,2%. Pacientes com DPP acentuada foram mais jovens e com maior IMC, mas menor diâmetro da via de saída do ventrículo esquerdo (DVSVE). As variáveis independentes que podem predizer DPP acentuada são: gênero masculino, IMC > 25 kg/m2, idade < 60 anos, DVSVE < 21 mm e etiologia reumática com área sob a curva ROC de 0,82. Conclusão: A frequência de DPP acentuada é alta em uma população brasileira submetida à TVA no Sistema Público de Saúde. Os principais determinantes de DPP acentuada são: valvopatia reumática, gênero masculino, IMC alto, idade < 60 anos e menor DVSVE.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Diseases/surgery , Reoperation , Echocardiography , Cross-Sectional Studies , Retrospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Hospitals, Public
12.
Arq. bras. cardiol ; 112(3): 292-301, Mar. 2019. tab, graf
Article in English | LILACS | ID: biblio-989329

ABSTRACT

Abstract Background: The choice of a mechanical (MP) or biological prosthesis (BP) for patients with valvular heart disease undergoing replacement is still not a consensus. Objective: We aimed to determine the clinical outcomes of MP or BP placement in those patients. Methods: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) that compared biological prostheses and mechanical prostheses in patients with valvular heart diseases and assessed the outcomes. RCTs were searched in the MEDLINE, EMBASE, LILACS, CENTRAL, SCOPUS and Web of Science (from inception to November 2014) databases. Meta-analyses were performed using inverse variance with random effects models. The GRADE system was used to rate the quality of the evidence. A P-value lower than 0.05 was considered significant. Results: A total of four RCTs were included in the meta-analyses (1,528 patients) with follow up ranging from 2 to 20 years. Three used old generation mechanical and biological prostheses, and one used contemporary prostheses. No significant difference in mortality was found between BP and MP patients (risk ratio (RR = 1.07; 95% CI 0.99-1.15). The risk of bleeding was significantly lower in BP patients than MP patients (RR = 0.64; 95% CI 0.52-0.78); however, reoperations were significantly more frequent in BP patients (RR = 3.60; 95% CI 2.44-5.32). There were no statistically significant differences between BP and MP patients with respect to systemic arterial embolisms and infective endocarditis (RR = 0.93; 95% CI 0.66-1.31, RR = 1.21; CI95% 0.78-1.88, respectively). Results in the trials with modern and old prostheses were similar. Conclusions: The mortality rate and the risk of thromboembolic events and endocarditis were similar between BP and MP patients. The risk of bleeding was approximately one third lower for BP patients than for MP patients, while the risk of reoperations was more than three times higher for BP patients.


Resumo Fundamento: A escolha de próteses mecânicas ou biológicas para pacientes com doença de válvula cardíaca ainda não é um consenso. Objetivo: Determinar os desfechos clínicos de próteses mecânicas e biológicas nesses pacientes. Métodos: Conduzimos uma revisão sistemática e metanálise e estudos controlados randomizados (RCTs) que compararam próteses mecânicas e biológicas em pacientes com doenças de válvulas cardíaca, e avaliamos seus resultados. A busca por RCTs foi feita nas bases de dados MEDLINE, EMBASE, LILACS, CENTRAL, SCOPUS e Web of Science (do início a novembro de 2014). As metanálises foram realizadas usando variação inversa com modelos de efeitos aleatórios. Usamos o sistema GRADE para avaliar a qualidade da evidência. Um valor menor que 0,05 foi considerado significativo. Resultados: Um total de quatro RCTs foi incluído na metanálise (1528 pacientes) com acompanhamento de 2 a 20 anos. Em três estudos, foram utilizadas próteses mecânicas e biológicas mais antigas, e em um estudo próteses contemporâneas. Não foi observada diferença de mortalidade entre os pacientes que receberam próteses mecânicas e biológicas (risco relativo, RR = 1,07; IC95% 0,99-1,15). O risco de sangramento foi significativamente mais baixo nos pacientes que receberam próteses biológicas que naqueles com próteses mecânicas (RR = 0,64; IC95% 0,52-0,78). Contudo, as reoparações foram mais frequentes em pacientes com próteses biológicas (RR = 3,60; IC95% 2,44-5,32). Não houve diferenças estatisticamente significativas entre pacientes com próteses biológicas e mecânicas em relação à embolia arterial sistêmica e endocardite infecciosa (RR = 0,93; IC95% 0,66-1,31; RR = 1,21; IC95% 0,78-1,88, respectivamente). Resultados entre os estudos com próteses modernas e antigas foram similares. Conclusões: A taxa de mortalidade e o risco de eventos tromboembólicos e endocardite foram similares entre os pacientes que receberam próteses biológicas e mecânicas. O risco de sangramentos foi aproximadamente um terço menor nos pacientes com próteses biológicas que mecânicas, ao passo que o risco de reoperação foi mais que três vezes maior nos pacientes com próteses biológicas.


Subject(s)
Humans , Heart Valve Prosthesis/standards , Heart Valve Diseases/surgery , Reoperation , Bioprosthesis , Randomized Controlled Trials as Topic , Treatment Outcome , Evidence-Based Medicine , Heart Valve Prosthesis Implantation/methods
15.
Arq. bras. cardiol ; 107(1): 55-62, July 2016. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-792497

ABSTRACT

Abstract Background: Paravalvular regurgitation (paravalvular leak) is a serious and rare complication associated with valve replacement surgery. Studies have shown a 3% to 6% incidence of paravalvular regurgitation with hemodynamic repercussion. Few studies have compared surgical and percutaneous approaches for repair. Objectives: To compare the surgical and percutaneous approaches for paravalvular regurgitation repair regarding clinical outcomes during hospitalization and one year after the procedure. Methods: This is a retrospective, descriptive and observational study that included 35 patients with paravalvular leak, requiring repair, and followed up at the Dante Pazzanese Institute of Cardiology between January 2011 and December 2013. Patients were divided into groups according to the established treatment and followed up for 1 year after the procedure. Results: The group submitted to percutaneous treatment was considered to be at higher risk for complications because of the older age of patients, higher prevalence of diabetes, greater number of previous valve surgeries and lower mean creatinine clearance value. During hospitalization, both groups had a large number of complications (74.3% of cases), with no statistical difference in the analyzed outcomes. After 1 year, the percutaneous group had a greater number of re-interventions (8.7% vs 20%, p = 0.57) and a higher mortality rate (0% vs. 20%, p = 0.08). A high incidence of residual mitral leak was observed after the percutaneous procedure (8.7% vs. 50%, p = 0.08). Conclusion: Surgery is the treatment of choice for paravalvular regurgitation. The percutaneous approach can be an alternative for patients at high surgical risk.


Resumo Fundamento: Regurgitação ou escape paravalvar é uma complicação grave e incomum associada ao implante de prótese valvar. Estudos mostram incidência de 3% a 6% com repercussão hemodinâmica. Existem poucos estudos na literatura que comparam as abordagens cirúrgica e percutânea para sua correção. Objetivos: Comparar as abordagens cirúrgica e percutânea de correção da regurgitação paravalvar quanto a desfechos clínicos durante a internação e após 1 ano do procedimento. Métodos: Este é um estudo retrospectivo, descritivo e observacional, que incluiu 35 pacientes com escape paravalvar acompanhados no Instituto Dante Pazzanese de Cardiologia entre janeiro de 2011 e dezembro de 2013 e que necessitaram de correção. Os pacientes foram divididos de acordo com o tratamento estabelecido e acompanhados por um período 1 ano após o procedimento. Resultados: O grupo submetido ao tratamento percutâneo foi considerado como de maior risco para complicações por apresentar pacientes mais idosos, com maior prevalência de diabetes, maior quantidade de cirurgias valvares prévias e menor valor médio de clearance de creatinina. Durante a evolução intra-hospitalar, observou-se grande número de complicações nos dois grupos (74,3% dos casos), sem diferença estatística nos desfechos analisados. Após 1 ano, o grupo percutâneo teve maior número de reintervenções (8,7% vs. 20%, p = 0,57) e mortalidade maior (0% vs. 20%, p = 0,08). Uma alta incidência de escape residual mitral foi verificada após procedimento percutâneo (8,7% vs. 50%, p = 0,08). Conclusão: A cirurgia é o tratamento de escolha da regurgitação paravalvar. A abordagem percutânea pode ser uma alternativa para os pacientes com risco cirúrgico elevado.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Percutaneous Coronary Intervention/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Aortic Valve/surgery , Aortic Valve Insufficiency/mortality , Postoperative Complications/surgery , Postoperative Complications/mortality , Reoperation , Time Factors , Bioprosthesis/adverse effects , Heart Valve Prosthesis/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Therapeutic Occlusion/methods , Therapeutic Occlusion/mortality , Percutaneous Coronary Intervention/mortality , Hospitalization , Mitral Valve/surgery , Mitral Valve Insufficiency/mortality
16.
Rev. Assoc. Med. Bras. (1992) ; 62(1): 32-37, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-777440

ABSTRACT

SUMMARY Introduction: the EuroSCORE II and STS are the most used scores for surgical risk stratification and indication of transcatheter aortic valve implantation (TAVI). However, its role as a tool for mortality prediction in patients undergoing TAVI is still unclear. Objective: to evaluate the performance of the EuroSCORE II and STS as predictors of in-hospital and 30-day mortality in patients undergoing TAVI. Methods: we included 59 symptomatic patients with severe aortic stenosis that underwent TAVI between 2010 and 2014. The variables were analyzed using Student's t-test and Fisher's exact test and the discriminative power was evaluated using receiver operating characteristic curve (ROC) and area under the curve (AUC) with a 95% confidence interval. Results: mean age was 81±7.3 years, 42.3% men. The mean EuroSCORE II was 7.6±7.3 % and STS was 20.7±10.3%. Transfemoral procedure was performed in 88.13%, transapical in 3.38% and transaortic in 8.47%. In-hospital mortality was 10.1% and 30-day mortality was 13.5%. Patients who died had EuroSCORE II and STS higher than the survivors (33.7±16.7vs. 18.6±7.3% p=0,0001 for STS and 13.9±16.1 vs. 4.8±3.8% p=0.0007 for EuroSCORE II). The STS showed an AUC of 0.81 and the EuroSCORE II of 0.77 and there were no differences in the discrimination ability using ROC curves (p=0.72). Conclusion: in this cohort, the STS and EuroSCORE II were predictors of in-hospital and 30-days mortality in patients with severe aortic stenosis undergoing TAVI.


RESUMO Introdução: STS e EuroSCORE II são os escores mais utilizados para a estratificação de risco cirúrgico e indicação do implante de válvula aórtica transcateter (TAVI). Entretanto, seu papel como ferramenta para predição de mortalidade em pacientes submetidos ao TAVI ainda é incerto. Objetivo: avaliar o desempenho do EuroSCORE II e STS como preditores de mortalidade intra-hospitalar em 30 dias em pacientes submetidos ao TAVI. Métodos: 59 pacientes com estenose aórtica importante submetidos ao TAVI entre 2010 e 2014. Variáveis foram analisadas por meio do teste t-Student e teste exato de Fisher, e o poder discriminativo foi avaliado pela curva ROC e área sob a curva, acompanhada de intervalo de confiança de 95%. Resultados: a idade média foi de 81±7,3 anos, 42,3% homens. Média do EuroSCORE II foi de 6,07±7,3%, e do STS, 20,7±10,3%. Procedimento transfemoral foi realizado em 88,13%, transapical, em 3,38% e transaórtico, em 8,47%. A mortalidade intra-hospitalar foi 10,1%, e em 30 dias, 13,5%. Os pacientes que evoluíram para óbito apresentavam STS e EuroSCORE II mais elevados que os sobreviventes (33,7±16,7% vs. 18,6±7,3%; p=0,0001 para STS e 13,9±16,1% vs. 4,8±3,8%; p=0,0007 para EuroSCORE II). O STS apresentou AUC de 0,81, e o EuroSCORE II, 0,77. Não houve diferença na capacidade de discriminação pelas curvas ROC (p=0,72). Conclusão: STS e EuroSCORE II foram preditores de mortalidade intra-hospitalar em 30 dias.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Brazil , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Hospital Mortality , Transcatheter Aortic Valve Replacement/adverse effects
17.
Rev. bras. cir. cardiovasc ; 29(4): 559-563, Oct-Dec/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-741740

ABSTRACT

Objetivo: Avaliar a influência do tipo de prótese na mortalidade intra-hospitalar no período de pós-operatório imediato nos pacientes que fizeram substituição de válvula. Métodos: Estudo transversal, em que dados, como sexo, origem, idade, etiologia, dados ecocardiográficos, o tipo de cirurgia realizada e da prótese utilizada em casos de substituição de válvula foram analisadas r etrospectivamente. Resultados: Foram revisados 353 prontuários de pacientes que realizaram cirurgia de troca valvar. A idade média foi de 41,87±17,9 anos. Em relação ao gênero, 52,8% eram do sexo feminino. Quanto à origem, 61,1% vieram de cidades do interior do estado. Do total de pacientes, 58,5% eram portadores da doença reumática. Avaliando o tipo de prótese implantada, 70% realizou troca por bioprótese e 30% metálica. A mortalidade hospitalar desse estudo foi de 11%, não havendo diferença significativa entre o tipo de prótese utilizada. Conclusão: O tipo de prótese utilizada não influenciou na mortalidade intra-hospitalar. .


Objective: To evaluate the influence of the type of prosthesis in-hospital mortality in the post-operative period in patients who had valve replacement. Methods: A cross-sectional data, such as gender, origin, age, etiology, echocardiograph data, the type of surgery performed and the prosthesis used in cases of valve replacement were analyzed retrospectively. Results: We reviewed 353 charts of patients who underwent valve replacement surgery. The mean age was 41.87±17.9 years. Regarding gender, 52.8% were female. As for the origin, 61.1% came from small cities within the state. Of all patients, 58.5% suffered from rheumatic disease. Assessing the type of prosthesis implanted, 70% held replace by bioprosthesis and 30% metallic. The hospital mortality in this study was 11%, with no significant difference between the types of prosthesis utilized. Conclusion: The type of implant used had no effect on in-hospital mortality. .


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Young Adult , Heart Valve Prosthesis , Hospital Mortality , Heart Valve Diseases/mortality , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/mortality , Age Factors , Bioprosthesis , Cross-Sectional Studies , Postoperative Period , Prosthesis Design , Retrospective Studies , Risk Factors , Sex Factors , Statistics, Nonparametric , Treatment Outcome
18.
Rev. bras. cardiol. invasiva ; 22(3): 216-224, Jul-Sep/2014. tab, graf
Article in Portuguese | LILACS-Express | LILACS, SES-SP | ID: lil-732779

ABSTRACT

Introdução: O implante por cateter de prótese aórtica (TAVI, do inglês transcatheter aortic valve implantation) constitui tratamento alternativo para pacientes com estenose aórtica de alto risco cirúrgico ou inoperáveis. Para adquirir competência, o grupo multidisciplinar deve receber treinamento específico e acumular experiência na execução do TAVI. Contudo, sua curva de aprendizado não está bem estabelecida. Nosso objetivo foi analisar o impacto da curva de aprendizado na seleção de pacientes, nos aspectos técnicos e nos resultados clínicos do TAVI. Métodos: Estudo observacional e prospectivo dos primeiros 150 pacientes submetidos a TAVI por via femoral, entre janeiro de 2009 e dezembro de 2013 divididos em tercis (n = 50) de acordo com a data do procedimento. Os desfechos foram definidos conforme os critérios Valve Academic Research Consortium-2 (VARC-2). Resultados: A idade foi de 82,5 ± 6,7 anos, sendo 44% homens e 75% em classe NYHA III/IV. O EuroSCORE (24,2 ± 13% vs. 21,2 ± 10,8% vs. 23,4 ± 14,3%) e o STS Score (5,9 ± 2,9% vs. 6,7 ± 4,3% vs. 5,8 ± 3,1%) foram similares entre os grupos. Observou-se redução gradativa nos tempos do procedimento (107,2 ± 48,1 minutos vs. 90,3 ± 42,2 minutos vs. 76,6 ± 37,7 minutos; p < 0,01) e de fluoroscopia (31,3 ± 9,6 minutos vs. 25,4 ± 8,7 minutos vs. 17,2 ± 6,2 minutos; p = 0,01), e no ...


Background: Transcatheter aortic valve implantation (TAVI) is an alternative treatment for high-risk or inoperable patients with aortic stenosis. The multidisciplinary team must undergo specific training and accumulate experience to achieve optimal results. However, its learning curve is not well established. Our objective was to investigate the impact of learning curve on patient selection, technical aspects and clinical outcomes of TAVI. Methods: Observational, prospective analysis of the first 150 patients undergoing transfemoral TAVI between January 2009 and December 2013. Patients were divided into tertiles (n = 50), according to the procedure date. Outcomes were defined according to Valve Academic Research Consortium-2 (VARC-2) criteria. Results: Mean age was 82.5 ± 6.7 years, 44% were male and 75% were in NYHA class III/IV. EuroS-CORE (24.2 ± 13% vs. 21.2 ± 10.8% vs. 23.4 ± 14.3%) and STS Score (5.9 ± 2.9% vs. 6.7 ± 4.3% vs. 5.8 ± 3.1%) were similar between groups. A gradual decrease was observed in procedure times (107.2 ± 48.1 minutes vs. 90.3 ± 42.2 minutes vs. 76.6 ± 37.7 minutes; p < 0.01), fluoroscopy times (31.3 ± 9,6 minutes vs. 25.4 ± 8.7 minutes vs. 17.2 ± 6.2 minutes; p = 0.01) and contrast volume (145.5 ± 70.9 mL vs. 123.2 ± 87.8 mL vs. 101.1 ± 50 mL; p = 0.01). Mortality decreased gradually (20% vs. 10% vs. 4%; p = 0,047), and lower bleeding and moderate-to-severe aortic regurgitation were ...

19.
Rev. bras. cir. cardiovasc ; 29(1): 59-68, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-710075

ABSTRACT

Introdução: Pacientes portadores de próteses valvares cardíacas mecânicas devem medicados continuamente com anticoagulantes orais para evitar acidentes tromboembólicos. Estes pacientes são avaliados continuamente para o controle da anticoagulação oral. Objetivo: Comparar a ocorrência de complicações tromboembólicas e hemorrágicas em portadores de próteses valvares cardíacas mecânicas de um (mono) e de dois (bi) folhetos na posição mitral em terapêutica anticoagulante. Métodos: Foram estudados, no intervalo de 10 anos, 117 pacientes portadores de prótese na posição mitral, sendo 48 com próteses de folheto único e 69 de folheto duplo. Avaliou-se a ocorrência de complicações tromboembólicas e hemorrágicas de grau maior e menor de acordo com a gravidade. Os resultados estão apresentados sob forma de estudo atuarial e de frequência linearizada de ocorrência de eventos. Resultados: As curvas atuariais mostraram que, ao longo do tempo, os pacientes portadores de próteses valvares monofolheto estiveram menos livres de complicações tromboembólicas que os pacientes com próteses bifolheto, enquanto que, estes últimos (bifolheto) estiveram menos livres de acidentes hemorrágicos. As frequências linearizadas de ocorrência para tromboembolismo foram maiores nos pacientes com próteses monofolheto. Nos episódios hemorrágicos as taxas foram maiores para os portadores de próteses bifolheto. Conclusão: Os portadores de próteses valvares cardíacas monofolheto mostraram-se mais propensos à ocorrência de acidentes tromboembólicos graves em relação aos com próteses bi folheto. Os pacientes com prótese bifolheto apresentaram maior sangramento que os pacientes com prótese ...


Introduction: Patients with mechanical heart valve prostheses must continuously be treated with oral anticoagulants to prevent thromboembolic events related to prosthetesis. These patients should be continually evaluated for the control of oral anticoagulation. Objective: To compare the occurrence of thromboembolic and hemorragic complications in patients with mechanical heart valve prosthesis with one (mono) and two (bi) leaflets in the mitral position in anticoagulant therapy. Methods: We studied the 10-year interval, 117 patients with prosthesis in the mitral position, 48 with prosthetic single leaflet and 69 with two leaflets. We evaluated the occurrence of thromboembolic and hemorrhagic major and minor degree under gravity. The results are presented in an actuarial study and the frequency of occurrence of linear events. Results: The actuarial survival curves showed that over time, patients with prosthetic heart valve with one leaflet were less free of thromboembolic complications than patients with two leaflet prosthetic valve, while the latter (two leaflet) were less free of hemorrhagic accidents. The linearized frequency of occurrence of thromboembolism were higher in patients with mono leaflet prosthesis. Bleeding rates were higher for patients with bi leaflet prosthetic valve. Conclusion: Patients with mono leaflet prosthetic heart valve showed that they are more prone to the occurrence of serious thromboembolic events compared to those with bi leaflet prosthetic valve. Patients with bi leaflet prosthetic valve had more bleeding than patients with mono leaflet prosthetic valve, however this difference was restricted to the bleeding of minor nature. .


Subject(s)
Adult , Female , Humans , Male , Heart Valve Prosthesis/adverse effects , Hemorrhage/etiology , Mitral Valve/surgery , Postoperative Complications/etiology , Prosthesis Design/adverse effects , Thromboembolism/etiology , Anticoagulants/therapeutic use , Heart Valve Prosthesis Implantation/adverse effects , Risk Factors , Time Factors
20.
Rev. bras. cir. cardiovasc ; 28(4): 462-469, out.-dez. 2013. ilus
Article in English | LILACS | ID: lil-703113

ABSTRACT

INTRODUCTION: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min.) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves.


INTRODUÇÃO: A caracterização hidrodinâmica in vitro de próteses de válvulas cardíacas fornece informações importantes quanto ao seu funcionamento, sobretudo se realizada por meio de métodos não-invasivos de anemometria. Uma vez obtidos os perfis de velocidade para cada válvula, é possível compará-las quanto ao seu desempenho hidrodinâmico. Neste primeiro estudo experimental de anemometria laser com válvulas mecânicas, as simulações foram realizadas em bancada de testes para escoamento permanente. OBJETIVO: Comparar perfis de velocidade unidimensional no plano central de duas próteses aórticas de duplo folheto St. Jude (modelos AGN 21 - 751 e 21 AJ - 501) submetidas a um regime de fluxo permanente, para quatro seções distintas, três à jusante e uma à montante. MÉTODOS: Proporcionar condições de similaridade para o escoamento através de cada prótese, por meio de bancada hidrodinâmica para escoamento permanente (água, à vazão de 17 L/min.) e, por meio de anemometria laser unidimensional, obter os perfis de velocidades para as mesmas seções e varreduras. RESULTADOS: Verificou-se que as maiores velocidades correspondem à prótese de diâmetro interno menor e que as instabilidades do fluxo são maiores à medida que a seção de interesse encontra-se mais próxima da válvula. Também foram verificadas as regiões de recirculação, de estagnação do fluxo e de baixa pressão, além dos picos de velocidade para o escoamento em questão. CONCLUSÕES: Sob o aspecto hidrodinâmico e para todas as seções de interesse, foi possível concluir a preferência da válvula de modelo AGN 21 - 751 (RegentTM) sobre a 21 AJ - 501 (Master Series). Os resultados obtidos permitiram escolher, para os próximos trabalhos, um foco de estudo mais específico para regiões concretas dessas próteses.


Subject(s)
Blood Flow Velocity , Heart Valve Prosthesis , Hydrodynamics , Laser-Doppler Flowmetry/methods , Materials Testing , Medical Illustration , Models, Cardiovascular , Pressure , Prosthesis Design , Reproducibility of Results , Time Factors